[ CURTAIN WALL ]

E-100 Semi structural

Sections and thicknesses

INTERIOR VIEW SECTIONS

  • Uprights: 54 mm 
  • Crossbars: 54 mm 

THEORETICAL AVERAGE THICKNESS

  • Between 2 mm and 8 mm

ARCHITRAVE OPTION

  • Rectangular 16 and 20 mm deep 
  • Round 46 mm deep 
  • Elliptical 90 mm deep 
Sizes and maximum weights
  • Awning-sliding-top hung opening 
  • WIDTH: 2,000 mm 
  • HEIGHT: 2,000 mm 
  • Maximum weight: 130kg 
Glazing
  • Up to 38 mm
Thermal transmittance and CTE compliance areas
  • UH transmittance from ??? (W/m2K) 
  • Consult typology, dimensions and glass
Test fixture categories
  • Reference test: 3940 x 3600 panel size with 1260 x 1545 window awning-sliding  
  • Fixed façade parts air permeability (UNE-EN 12153-2000) 
    CLASS: 4E 
  • Casement façade parts air permeability (UNE-EN 12153-2000) 
    CLASS: 4 
  • Water tightness (UNE-EN 12155-2000) 
    CLASS: RE750 
  • Wind resistance loads (design pressure: 1200Pa/ -1200 Pa). As per UNE-EN 12179-2000 Standard 
    SUITABLE 
  • Resistance to external impact (450 mm drop height). As per UNE-EN 14019:2004 Standard 
    CLASS: E3 
  • resistance to internal impact (450 mm drop height). As per UNE-EN 14019:2004 Standard 
    CLASS: I3 
Opening possibilities

  • Hidden awning-sliding-top hung
Finishes
  • Bicolour option 
  • Lacquered colours (RAL, flecked and rugged ) 
  • Wood effect lacquered
  • Anodised 

Section